Fire Cables
They are designed to meet specific requirements for solar installations, including resistance to UV radiation and extreme temperatures. They are made with materials that provide excellent insulation and protection against environmental factors, ensuring the long-term reliability and safety of the solar power system.
CU/MICA/LSOH
CONSTRUCTION
1. CONDUCTOR
Copper, semi-rigid class 2
2. Fire Resistance Material
MICA Glass Tape
3. INSULATION
Low Smoke Zero Halogen [LSOH]
Rated Voltage:Â 450/750 V
APPLICATION
These cables are used in hazardous areas where safety and circuit integrity are highly required during fire conditions.
CU/MICA/XLPE/LSOH
CONSTRUCTION
1. CONDUCTOR
Copper, semi-rigid class 2
2. Fire Resistance Material
MICA Glass Tape
3. INSULATION
Cross Linked Polyethylene (XLPE)
4. SHEATH
Low Smoke Zero Halogen [LSOH]
Rated Voltage:Â 0.6/1 kv
APPLICATION
These cables are used in hazardous areas where safety and circuit integrity are highly required during fire conditions.
STANDARDS
IEC 60502-1
IEC 60228
CU/MICA/XLPE/LSOH
CONSTRUCTION
1. CONDUCTOR
Copper, semi-rigid class 2
2. Fire Resistance Material
MICA Glass Tape
3. INSULATION
Cross Linked Polyethylene (XLPE)
4. SHEATH
Low Smoke Zero Halogen [LSOH]
Rated Voltage: 0.6/1 kv
APPLICATION
These cables are used in hazardous areas where safety and circuit integrity are highly required during fire conditions.
STANDARDS
IEC 60502-1
IEC 60228
CU/MICA/XLPE/SWA/LSOH
CONSTRUCTION
1. CONDUCTOR
Copper, semi-rigid class 2
2. Fire Resistance Material
MICA Glass Tape
3. INSULATION
Cross Linked Polyethylene (XLPE)
4. ARMOUR
Galvanized Round Steel Wire
5. SHEATH
Low Smoke Zero Halogen [LSOH]
Rated Voltage: 0.6/1 kv
APPLICATION
These cables are used in hazardous areas where safety and circuit integrity are highly required during fire conditions.
STANDARDS
IEC 60502-1
IEC 60228
CU/MICA/XLPE/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used for interconnecting control devices mainly in
hazardous areas where safety and circuit integrity are highly required
during fire conditions.
CU/MICA/XLPE/SWA/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Armour
Galvanized Round Steel Wire (GSWA)
5. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used for interconnecting control devices mainly in
hazardous areas where safety and circuit integrity are highly required
during fire conditions.
CU/MICA/XLPE/OS/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Shielding
Overall Shielded
5. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used as signal carrier for connecting electrical instrument
circuits mainly in hazardous areas where safety and circuit
integrity are highly required during fire conditions.
CU/MICA/XLPE/IS/OS/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Shielding
Individual & Overall Shielded
5. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used as signal carrier for connecting electrical instrument
circuits mainly in hazardous areas where safety and circuit
integrity are highly required during fire conditions.
CU/MICA/XLPE/OS/SWA/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Shielding
Overall Shielded
5. Armour
Galvanized Round Steel Wire (GSWA)
6. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used as signal carrier for connecting electrical instrument
circuits mainly in hazardous areas where safety and circuit integrity are
highly required during fire conditions.
CU/MICA/XLPE/IS/OS/SWA/LSOH
CONSTRUCTION
1. CONDUCTOR
Stranded Copper class 2
2. Fire Resistance Material
MICA Glass Tape
3. Insulation
Cross Linked Polyethylene (XLPE)
Alternative: Low Smoke Zero Halogen (LSOH)
4. Shielding
Individual & Overall Shielded
5. Armour
Galvanized Round Steel Wire (GSWA)
6. Sheath
Low Smoke Zero Halogen (LSOH)
APPLICATION
These cables are used as signal carrier for connecting electrical instrument
circuits mainly in hazardous areas where safety and circuit integrity are
highly required during fire conditions.