Single Core

Copper

View Details

Single Core

Aluminum

View Details

Low Voltage Power Cables

Low-voltage power cables are designed to transmit power at voltage up to 3.3 KV.        These cables are commonly used in various applications, including residential, commercial, and industrial settings.

CU/PVC/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC] 
Alternative: Cross-Linked polyethylene [XLPE]
3. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For outdoor and indoor installations in dump and wet locations.They
are normally used for power distribution in urban networks and industrial
plants, as well as in thermopower and hydropower stations.
Maximum operating temperature: Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1

IEC 60228

AL/PVC/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
Alternative: Cross-Linked polyethylene [XLPE]
3. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations.
They are normally used for power distribution in urban networks,
industrial plants as well as in thermopower and hydropower stations.
Maximum operating temperature: 90°C

 

STANDARDS

IEC 60502-1
IEC 60228

CU/PVC/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
3. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For outdoor and indoor installations in dump and wet locations.
Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1
IEC 60228

CU/PVC/STA/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
3. ARMOUR
Double Steel Tape
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations, Where mechanical damage is expected to occur.
Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1
IEC 60228

AL/PVC/STA/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
3. ARMOUR
Double Steel Tape
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations, Where mechanical damage is expected to occur.
Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1
IEC 60228

CU/PVC/SWA/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
3. ARMOUR
Galvanized Round Steel Wire
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations, Where mechanical damage is expected to occur.
Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1
IEC 60228

AL/PVC/SWA/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Polyvinyl Chloride [PVC]
3. ARMOUR
Galvanized Round Steel Wire
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations, Where mechanical damage is expected to occur.
Maximum operating temperature: 70°C

STANDARDS

IEC 60502-1
IEC 60228

CU/XLPE/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Cross-Linked polyethylene [XLPE]
3. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

Semi-rigid for use in low voltage power distribution in fixed
indoor and outdoor installations.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

AL/XLPE/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Cross-Linked polyethylene [XLPE]
3. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 KV

APPLICATION

For indoor and outdoor installations in damp and wet locations.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

CU/XLPE/STA/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Cross-linked polyethylene [XLPE]
3. ARMOUR
Double Steel Tape
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 Kv

APPLICATION

For indoor and outdoor installations in damp and wet locations.
Where mechanical damage is expected to occur.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

AL/XLPE/STA/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Cross-linked polyethylene [XLPE]
3. ARMOUR
Double Steel Tape
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 Kv

APPLICATION

For indoor and outdoor installations in damp and wet locations.
Where mechanical damage is expected to occur.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

CU/XLPE/SWA/PVC

CONSTRUCTION

1. CONDUCTOR
Copper, semi-rigid class 2
2. INSULATION
Cross-linked polyethylene [XLPE]
3. ARMOUR
Galvanized Round Steel Wire
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage:  0.6/1 Kv

APPLICATION

For indoor and outdoor installations in damp and wet locations.
Where mechanical damage is expected to occur.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

AL/XLPE/SWA/PVC

CONSTRUCTION

1. CONDUCTOR
Aluminum, semi-rigid class 2
2. INSULATION
Cross-linked ployethylene [XLPE]
3. ARMOUR
Galvanized Round Steel Wire
4. SHEATH
Polyvinyl Chloride [PVC]
Rated Voltage: 0.6/1 Kv 

APPLICATION

For indoor and outdoor installations in damp and wet locations.
Where mechanical damage is expected to occur.
Maximum operating temperature: 90°C

STANDARDS

IEC 60502-1
IEC 60228

Product Inquiry

Please enable JavaScript in your browser to complete this form.
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.